What it exposes
| Feature | Property | Values | Control |
|---|---|---|---|
| Liquid state | liquid_state | low, normal, high | read only |
| Liquid level percent | liquid_level_percent | % | read only |
| Liquid depth | liquid_depth | m | read only |
| Voltage | voltage | V | read only |
| Max set | max_set | % · 0…100 | settable |
| Min set | min_set | % · 0…100 | settable |
| Liquid depth max | liquid_depth_max | m · 0.1…10 | settable |
| Relay switch | relay_switch | — | settable |
| Pump mode | pump_mode | supply, drainage | settable |
| Pump control | pump_control | auto, manual | settable |
| Version | version | — | read only |
MQTT: state and commands
Zigbee2MQTT publishes the device state to zigbee2mqtt/my_device (my_device is the name you give the device). An example message:
{
"liquid_state": "low",
"liquid_level_percent": 0,
"liquid_depth": 0,
"voltage": 230,
"max_set": 50,
"min_set": 50,
"liquid_depth_max": 5,
"relay_switch": false,
"pump_mode": "supply",
"pump_control": "auto",
"linkquality": 120
}
Send commands to zigbee2mqtt/my_device/set:
mosquitto_pub -t zigbee2mqtt/my_device/set -m '{"relay_switch":true}'
mosquitto_pub -t zigbee2mqtt/my_device/set -m '{"pump_mode":"drainage"}'
mosquitto_pub -t zigbee2mqtt/my_device/set -m '{"pump_control":"manual"}'
Watch the topics live from the browser: MQTT client.
How to pair it
- In Zigbee2MQTT click Permit join.
- Put the device in pairing mode: usually a long press of the reset button (5–10 s) until the LED blinks; bulbs: switch the power off and on 5–6 times.
- Keep the device close to the coordinator or a router while pairing.
- Give it a clear name: MQTT topics and Home Assistant entities are built from it.
Exact procedure and model notes: the device page in the Zigbee2MQTT docs. No coordinator yet: coordinator picker.